View CartMy Account / Order StatusHelp
Baldor Teco US Motors Leeson Sterling IFM Efector AC Tech

Join our mailing list!






Transaction Processing




baldor
leeson
sterling
teco
usmotors
actech
ifmefector
ac electric motors
ac tech drives
ac tech mc drives
ac tech scf drives
ac tech scd drives
teco ev drives
teco n3 drives
teco ma7200 drives
baldor drives
baldor vs1sp drives
baldor vs1sp washdown drives
baldor vs1gv drives
baldor vs1gv washdown drives
baldor vs1sd drives
baldor vs1sd washdown drives
baldor ac
baldor generators
baldor dc
meltric switch rated plugs
meltric dead front conntection
meltric
baldor motor sales
baldor ac motors
leeson ac motors
lincon ac motors
sterling ac motors
teco ac motors
us motors ac motors
electric motors
baldor dc motors
leeson dc motors
sterling dc motors
us motors dc motors
baldor brake motors
gear motors
baldor ac gearmotors
baldor dc gearmotors
ifm proximity sensors
ifm actuator sensors
ifm photoelectric sensors
ifm speed monitors
ifm wiring solutions
ifm sensor accessories
ac tech variable drives
baldor variable drives
eaton variable drives
teco variable drives
variable drive accessories
koyo radial ball bearings
koyo tapered roller bearings
koyo spherical roller bearings
koyo cylindrical roller bearings
koyo angular contact thrust bearings
leeson motors sales
power components teco westinghouse
(Your shopping cart is empty)

  Home > Variable Drives > BALDOR >

  1 HP 240V NEMA 1 INVERTER DRIVE, BALDOR # VS1SP61-1B
  BALDOR VS1SP61-1B1
BALDOR VS1SP61-1B1
CALL TOLL-FREE:
866-548-3611

 
Key Industries:
Food / Beverage Paper / Forest Products Petroleum / Chemical Unit / Baggage Handling Air Handling Pump / Fluid Handling Aggregate / Cement Mining Power Generation


List Price: $1,182.80
Sale Price: $745.16

Horse Power: 1
Voltage: 240
Phase: SINGLE
Enclosure: NEMA 1

Availability: Usually Ships in 24 to 48 Hours
Product Code: VS1SP61-1B1
Qty:


Product Overview
 
The VS1SP AC Drive uses a traditional inverter V/Hz control method. Its easy setup, quick startup, and right-out-of-the-box operation make it among the most popular variable speed motor controls. It is ideal for applications where multiple motors are operated simultaneously from one motor control, including pumps, fans, and general machinery applications.

For single motor operation, the VS1SP drive is also encoderless, which allows better speed and current control for high-performance, open-loop applications. Available in horsepowers from 3/4 to 125 HP and voltage ranges from 180-660 volts, these drives incorporate a variety of features and design innovations that ensure dependable performance.

Additionally, it provides the same interface as the Baldor V*S Drives sensorless vector products so that commonality is maintained within your facility for both closed loop and open loop applications.
 
Features
  • Current Ratings
     
  • Catalog Number
  •  
  • Input Volt
  •  Size
    VS1SP61-1B* 96-144/180-264 AA
  •  
     Standard 2.5 kHz
  • PWM
  •   
  • Constant Torque (Heavy
  • Duty)
  •      Input
  • Amp:  12
  •      HP: 1
  •      KW: 0.75
  •      IC:  4.20
  •      IP: 
  • 7.40
  •  
  • Variable Torque (Normal
  • Duty)
  •      Input
  • Amp: 20
  •      HP: 2
  •      KW: 1.50
  •      IC: 6.80
  •      IP: 7.80
  •  
  •  Quiet 8.0 kHz PWM
  •  
  • Constant Torque (Heavy
  • Duty)
  •      Input
  • Amp:  7.4
  •      HP: 0.75
  •      KW: 0.56
  •      IC:  3.2
  •      IP: 
  • 5.6
  •  
  • Variable Torque (Normal
  • Duty)
  •      Input
  • Amp: 12
  •      HP: 1
  •      KW: 0.75
  •      IC: 4.2
  •      IP: 4.8
  •  
    Specifications
     
  • Approvals
  •     
  •  
  • Input
  • Ratings
  • Frequency
  • 50/60 HZ ± 5%
  • Phase
  • Three phase (or single phase power with derating)
  • Impedance
  • 1% minimum from mains connection
  •  
  • Output
  • Ratings
  • Overload
  • Capacity
  • Constant Torque = 150% for 60 seconds,
  • 175% for 3 seconds
  • Variable Torque = 115% for 60 seconds
  • Frequency
  • 0-500Hz
  • Voltage
  • 0 to Maximum Input voltage (RMS)
  •  
  • Protective Features
  • Trip
  • Missing control power, over current, over voltage, under
  • voltage, Over temperature (motor or control), output shorted or
  • grounded, motor overload
  • Stall Prevention
  • Over voltage suppression, overcurrent suppression
  • External Output
  • LED trip condition indicators, 4 assignable logic outputs, 2
  • assignable analog outputs 0-10 VDC, ± 10 VDC
  • Short Circuit
  • Phase to phase, phase to ground
  •  
  • Environmental Conditions
  • Temperature
  • -10 to 45° C Derate 3% per degree C to maximum ambient
  • temperature of 55° C
  • Cooling
  • Forced air
  • Altitude
  • Sea level to 3300 feet (1000 Meters) derate 2% per 1000 feet
  • (303 Meters) above 3300 feet
  • Humidity
  • 10 to 90% RH non-condensing
  • Shock
  • 1G
  • Vibration
  • 0.5G at 10Hz to 60Hz
  • Storage Temperature
  • -10° to +65° C
  • Duty Cycle
  • 1.0
  •  
  • Keypad
  • Display
  • Display
  • LCD Graphical 128x64 Pixel
  • Keys
  • 14 key membrane with tactile response
  • Functions
  • Output status monitoring
  • Digital speed control
  • Parameter setting and display
  • Diagnostic and Fault log display
  • Motor run and jog
  • Local/Remote modes
  • LED Indicators
  • Forward run command
  • Reverse run command
  • Stop command
  • Jog active
  • Remote Mount (optional)
  • 200 feet (60.6m) maximum from control
  • Trip
  • Separate message and trace log for each trip, last 10 trips
  • retained in memory
  •  
  • Control
  • Specs
  • Control Method
  • Microprocessor controlled PWM output, selectable encoderless
  • vector or V/Hz inverter
  • PWM Frequency
  • Adjustable 1-5kHz STD, 5-16 kHz quiet
  • Frequency Setting
  • ± 5 VDC, 0-5 VDC ± 10 VDC, 4-20 mA, 0-20 mA; digital (keypad),
  • Serial Comms/USB 2.0, and Modbus RTU standard
  • Accel/Decel
  • 0-3600 seconds
  • V/Hz Ratio
  • Linear to squared reduced, base frequency, output voltage,
  • minimum frequency limit, maximum frequency limit
  • Torque Boost
  • 0-30% of input voltage; automatic with manual override
  • Brake Torque
  • 20% standard on Sizes AA and B, 1% standard on Size C
  • Skip Frequency
  • Three zones 0-Max frequency
  • Velocity Loop
  • Bandwidth
  • Adjustable to 180 Hz (Control only)
  • Current Loop
  • Bandwidth
  • Adjustable to 1200 Hz (Control only)
  • Quiet PWM
  • Frequency Version
  • Full rating 5-8 kHz PWM frequency, Adjustable to 16 kHz with
  • linear derating (between 8-16kHz) of 50% at 16 kHz. 600VAC
  • controls do not allow operation above 2.5kHz
  • Standard PWM
  • Frequency Version
  • Full rating 1-2.5 khz PWM frequency, Adjustable to 5 kHz with
  • linear derating (between 2.5 - 5kHz) of 20% (240VAC) at 5 kHz
  • Adjustable to 5 kHz with linear derating (between 2.5 - 5kHz) of
  • 25% (480/600VAC) at 5 kHz
  • PC Setup Software
  • Workbench Software available using the USB2.0 port for
  • commissioning wizard, firmware download, parameter viewer, scope
  • capture and cloning
  • Operating modes include:
  • Keypad
  • Standard Run, 2 Wire
  • Standard Run, 3 Wire
  • 15 Preset Speeds
  • Fan Pump 2 Wire
  • Fan Pump 3 Wire
  • Process Mode
  • 3 SPD ANA 2 Wire
  • 3 SPD ANA 3 Wire
  • Electronic Pot 2 Wire
  • Electronic Pot 3 Wire
  • Network
  • Profile Run
  • 15 Preset Positions *
  • Bipolar
  • Pulse Follower *
  • PLC

  • * The modes not available for VS1SP Inverter
  •  
  • Differential Analog Input
  • Full Scale Range
  • ± 5VDC, ± 10VDC, 4-20 mA and 0-20 mA
  • Resolution
  • 11 bits + sign
  •  
  • Single Ended Analog Input
  • Full Scale Range
  • 0-10 VDC (0 to + 10VDC are valid inputs), 4-20 mA and 0-20 mA
  • Resolution
  • 11 bits + sign
  •  
  • Analog Outputs
  • Analog Outputs
  • 2 Assignable
  • Full Scale Range
  • ± 10VDC or 0 to 20mA
  • Source Current
  • 1 mA maximum
  • Resolution
  • 9 bits + sign
  •  
  • Digital Inputs
  • Opto-isolated Inputs
  • 9 Assignable
  • Rated Voltage
  • 10-30 VDC (closed contacts std)
  • Input Impedance
  • 4.71 k Ohms
  • Update Rate
  • 16 msec
  •  
  • Digital Outputs
  • (2 Opto Outputs)
  • Rated Voltage
  • 5 to 30 VDC
  • Maximum Current
  • 60 mA Maximum
  • ON Voltage Drop
  • 2 VDC Maximum
  • Output Conditions
  • 25 Conditions
  •  
  • Digital Outputs
  • (2 Relay Outputs)
  • Rated Voltage
  • 5 to 30 VDC or 240 VAC
  • Maximum Current
  • 5A Maximum non-inductive
  • Output Conditionns
  • 25 Conditions
  •  
  • Diagnostic Indications:
    • Current Sense Fault
    • Ground Fault
    • Instantaneous Over Current
    • Overload
    • Line Power Loss
    • Microprocessor Failure
    • Over temperature (Motor or Control)
    • Over Speed
    • Regeneration (db) Overload
    • Soft Start Fault
    • Under Voltage
    • Ready
    • Parameter Loss
    • Overload
    • Overvoltage
    • Torque Proving
    • Following Error
    • Encoder Loss
    • Logic Power Fault
    • PWR Base Fault

Similar Products...
Baldor VS1SP525-1B Baldor VS1SP475-1B Baldor VS1SP220-1B Baldor VS1MD43
Sale Price: $4,372.50
Add
Sale Price: $9,218.82
Add
Sale Price: $3,382.72
Add
Sale Price: $621.69
Add
Baldor VS1SP525-1B Baldor VS1SP475-1B Baldor VS1SP220-1B Baldor VS1MD43
Baldor VS1SP47-1B Baldor VS1SP240-1B Baldor VS1SP520-1B Baldor VS1MX11-4
Sale Price: $1,928.67
Add
Sale Price: $6,258.24
Add
Sale Price: $3,535.36
Add
Sale Price: $530.26
Add
Baldor VS1SP47-1B Baldor VS1SP240-1B Baldor VS1SP520-1B Baldor VS1MX11-4


 Share your knowledge of this product with other customers... Be the first to write a review.



Browse for more products in the same category as this item:

Variable Drives > BALDOR
HP > 1 HP
Phase > Single
Voltage > 230
Enclosure > NEMA 1
IndustrialLive.com
P.O. Box 3806
Modesto, CA 95352
 About Us
 Become an Affiliate
 Privacy Policy
 Send Us Feedback
 

Product pricing & availability is subject to change without notice.

Toll Free : 866.548.3611 Hours: M - F, 8 am - 5 pm PST
Company Info | Advertising | Product Index | Help | Terms of Use
Copyright © 2007 Industrial Live. All Rights Reserved.
eCommerce Powered by Volusion